Technical parameters of construction waste chutes are an important basis for selection, installation, acceptance and safe use. Longkang HDPE plastic construction waste chutes adopt a standardized design, and all parameters have undergone strict testing. This article introduces the core technical parameters in detail.
- Specification Parameters
| Parameter |
Light-duty |
Standard |
Heavy-duty |
| Nominal diameter |
400mm |
500mm |
600mm |
| Outer diameter |
400±2mm |
500±2mm |
600±2mm |
| Inner diameter |
388–394 mm |
488–494 mm |
588–594 mm |
| Wall thickness |
6±0.5mm |
8±0.5mm |
10±0.5mm |
| Length per section |
1200mm |
1500mm |
1500mm |
| Weight per section |
approx. 12kg |
approx. 20kg |
approx. 30kg |
| Connection method |
Quick-release buckle |
Quick-release buckle |
Quick-release buckle |
- Material Parameters
HDPE raw material properties:
- Density: 0.945–0.955 g/cm³
- Tensile yield strength: ≥20MPa
- Elongation at break: ≥500%
- Charpy impact strength (23℃): ≥15kJ/m²
- Low-temperature embrittlement temperature: ≤-40℃
- Melt flow rate: 0.3–0.7 g/10min
- Shore hardness D: ≥60
- Carbon black content: 2%–3% (Weather-resistant)
- Oxygen index: ≥17% (Standard) / ≥26% (Flame-retardant)
III. Mechanical Performance Parameters
- Pressure-bearing capacity
- Per-section vertical load capacity: Light-duty 200kg / Standard 400kg / Heavy-duty 600kg
- Overall pipe load capacity: calculated by fixing point spacing, ≤150kg per span
- Impact test: 5kg concrete block free-fall impact from 10m height, no cracks
- Wind load resistance
- Design wind speed: 28m/s (Beaufort force 10 wind)
- Fixing point spacing: ≤4m
- Maximum pipe swing: ≤100mm
- Connection strength
- Buckle tensile resistance: ≥5kN
- Sealing ring compression set: ≤20%
- Connection sealing: 0.05MPa air pressure, no leakage
- Throughput Parameters
| Parameter |
Light-duty |
Standard |
Heavy-duty |
| Cross-sectional area |
0.12m² |
0.19m² |
0.27m² |
| Maximum lump size |
250mm |
350mm |
450mm |
| Maximum single-piece weight |
5kg |
10kg |
15kg |
| Design falling speed |
15m/s |
18m/s |
20m/s |
| Daily processing capacity |
10–15 m³ |
18–25 m³ |
25–35 m³ |
| Hourly processing capacity |
1–2 m³ |
2–3 m³ |
3–4 m³ |
- Environmental Parameters
- Temperature range
- Operating temperature: -40℃ – +60℃
- Storage temperature: -20℃ – +40℃
- Transport temperature: -30℃ – +50℃
- High-temperature softening point: approx. 120℃ (HDPE melting point)
- Weather resistance
- Outdoor UV aging: elongation retention ≥50% after 5 years
- Chemical corrosion resistance: acid-resistant, alkali-resistant, cement-slurry-resistant
- Water resistance: water absorption <0.01%
- Noise performance
- Waste falling noise (500mm Standard): 60–70 dB(A)
- Measured at 1m distance
- 15–20 dB lower than steel
- Interface Parameters
- Standard section interface
- Connection type: socket-and-spigot + quick-release buckle
- Sealing ring: EPDM rubber, cross-section Φ8mm
- Interface diameter is the same as the pipe body
- Interface length: 50mm
- Fixing clamp interface
- Clamp width: 50mm
- Clamp material: galvanized steel strip or stainless steel
- Bolts: M10 stainless steel
- A clamp position is provided at the middle of each section
- Feed inlet parameters
- Feed inlet size: 300×400mm (Standard)
- With movable door: steel plate or plastic door
- Door sealing: rubber strip
- Door opening angle: 180°
- Discharge outlet parameters
- Discharge outlet diameter: same as pipe body
- Can be connected to a canvas flexible joint
- Optional sealed door
- Optional dust extraction interface DN100
VII. Dimensional Tolerances
- Diameter tolerance: ±2mm
- Wall thickness tolerance: ±0.5mm
- Length tolerance: ±5mm
- Out-of-roundness: ≤3mm
- End face perpendicularity: ≤2mm
VIII. Safety Parameters
- Feed inlet splash prevention: movable door and observation window provided
- Bottom safety distance: discharge outlet to collection hopper ≤500mm
- Protective net: protective net installed above the feed inlet
- Warning signs: warning signs installed every 10m along the pipe
- Grounding: grounding terminal provided for the anti-static type (optional)
- Longkang Parameter Commitment
All Longkang technical parameters have been laboratory tested and engineering-verified; each shipment includes:
- Product certificate
- Material test report
- Factory inspection record
- User manual
- Installation instruction drawing set