Linen refers to bed sheets, bed linens, bath towels and towels in hotel rooms. Accordingly, this system is also known as a linen chute system, hotel linen chute, linen slide, linen shaft, laundry chute or linen duct.

Main applications: collection and transfer of bedding in hotels, guesthouses and hospital wards within high-rise buildings, through the complete process to the laundry room. It achieves one-step, systematic, controlled, automated and intelligent handling, improving the efficiency of this otherwise cumbersome work: housekeeping staff simply drop linen at the end of the corridor and it reaches the laundry room.
Introduction: The chute is generally rolled from stainless steel sheet into a cylindrical section (square ducts are also available). Assembled so that the inner wall has no obstructing protrusions, burrs or barbs that could scratch bedding, the sections form a smooth, free-flowing channel from top to bottom; linen enters at the feed opening and descends smoothly.
Pipe connections demand a high standard; sealing requirements are moderate, but installation is more demanding and precise than a chimney, with height deviation controlled to about 50 mm at each section.
System composition (bottom to top): central control system, fire-rated discharge outlet, turning elbow, straight section, feed chute, floor-level feed door with fire and electric control, floor control box, and at the top an inspection door, fan and weather-cap exhaust system; cleaning, disinfection and fire-sprinkler systems can also be configured.
Dimensions: barrel diameter 500–610 mm, single wall; feed door 400×400 mm to 500×500 mm, double-layer fire door; material stainless steel 304/2B, barrel wall thickness 1.3–1.5 mm, door wall thickness 1.3 mm, discharge bend bottom thickened to 2.5–3 mm; inspection door 450×450 mm; exhaust pipe diameter 250 mm.
System control: the chute uses a 24 V integrated modular smart control system; feed doors can be opened by card swipe, password or fingerprint. When one door is open, the others lock automatically. Functions include fire sprinkler linkage, automatic locking of the high-temperature discharge door, exhaust-fan ventilation when a door opens, working-status indication and buzzer alarm; cleaning and disinfection functions can be added.

Installation: installation starts from the bottom; after the support is fixed, sections rise upward, allowing height adjustment before the feed doors are fitted. Installation is flexible: dedicated brackets or angle/channel steel can be fabricated on site. In socket-welded joints, avoid burning through the barrel; folded-edge welding avoids misalignment, and flange connections avoid excessive deviation.

System advantages: